Product Details:
Payment & Shipping Terms:
|
Material: | ABS Or PBT | Performance: | Categary 5 Performance |
---|---|---|---|
Pairs: | 10Pair | P.N.: | YH-2810B |
Protector: | 2814SP | Protector Pair: | 1Pair |
High Light: | connect modules,idc module |
10Pair Quick Connect Module with Gel 10 Pair Toolless Jumpering 2810B 3M
Quick Detail:
1, Material: PBT or ABS(UL94V-0)
2, Tool-less Jumpering .
3, Gelled interconnect.
4, Visibility to Jumpers.
5,Category 5 performance.
6, Pair-at-once termination
7, Low termination force
Description:
Advantage: Each protection module protects one pair at a time.
Single Pair Protector 2814SP is intended for use in a protected entrance terminal with a Quick Connect System (QCS) 2814-A or 2814-B. Each module protects one pair of telecommunication wires from voltage spikes.2814SPG is for indoor or outdoor terminals,2814SPD is for indoor terminals only.The protectors shall be coordinated with NO. 26 AWG or physically smaller fuse link wire.
Plug the protector into the 3M QCS blocks 2814-A or 2814-B. The protection module orange cap should be facing out, the grounding element on the protection module should be facing up, and the 3M on the orange cap should be oriented right side up. Ensure that the protector is fully inserted into the protector interface on the 3M QCS 2814 block. Each protection module protects one pair at a time.
To remove a protector, grab the top and bottom of the protection module with thumb and forefinger or using the 3M Single Pair Test Probe 2827 and pull firmly.
Jumping wire running
1. Open the feeder pair jumper cap on the protector module by pushing up on the latch and rotating up. Insert jumper wire ends A (tip) left and B (ring) right into wire openings in cap, making sure they are inserted all the way to the back of the cap.
2.While holding the jumper wires in place, close the cap and press to snap latch firmly into place
3. Route jumper wires to distribution pair through wire loops on block ends and through vertical and horizontal wireways. Cut jumper wires to appropriate length, leaving at least 5 cm (2 inches) of slack.
4. To remove jumper wires, open the cap and pull the wires straight out from block.
YH-2827 Single pair test probe for YH-2810B 10pair quick connect modules.
We offer various modules in telecommunication application, the products includes 5pair LSA type connection and disconnection module, 8pair and 10 pair connection disconnection krone module,back mount function and profile function, switching module,10pair Earth connection module, high band modules, 3M type quick connect module, 25pair splicing module, 10pair STG module, Subscriber terminal block, 50pair and 100pair krone block tag, back-mount frames, and other related accessories like LSA patch cord for disconnection and switching modules,earth bar,dust cover,label holder and so on.
The disconnection type CT module have provision of testing the electrical parameters of the exchange and distribution sides by insertion of test plug without actually disconnecting the jumper wire or the cable from the termination module.
The module housing material we mainly offer with imported GE PBT and ABS(UL94V-0).Both material we will use new rall material but not recycling material(first recycling or second recycling).So we can offer good performance modules.You can get very cheap products in the market but they are mainly made of such recycling material PBT or ABS.
Original Part No. C39407-A139-A12,YH-8073R Termination Tool for Series 5000, 5000compact, 1000RT, 71,red and grey
Original Part No. C39407-A139-A09,YH-8073B For Siemens 71series terminal block termination,blue and grey
Original Part No. C39407-A139-A13,YH-8073G For Siemens 1001/2001series terminal block termination,Green and grey
Crimping tool E-9BM for 3M connectors UY,UB,UR, UG,UIB,UIY,UAL, UBCO,UYCO,UIR, UDW,UDM,Super mini,cross.
Huawei type punch down tools DXD1.
8071Bix type insertion tool,Inserter wire 9A
8072Porta insertion tool Inserter wire 8A,used on jack tests
Simple crimping tool for 3M connectors UY,UR,UG
8077Insertion tool for Quante ID3000 MDF
8078Sunsea XD-B1 insertion tool
ZTE MDF compact punch down tool,FA6-09A1 FA6-09A2 FA6-09B1 FA6-09B2
1. 110 punch down tool
2. Quante 3 in 1 tool
3. Quante ID 85 tool (A)
4. Quante Pouyet STG Tool
5. MDF termination tool
6. Northern telecom type punch down tool
Professional Compression Coaxial F connector crimping tools PCT-AIO-CT
Applications:
High speed LAN and WAN systems,used to connect the Telecom and Data wires with punch down tools.
Specifications :
Mechanical Performance | Insertion force : 40~75N |
Pull Out Force : F≥25N(axial) F≥7.5N(radial) | |
IDC Life : 200 times(20-26 AWG Solid wire) minimum | |
Copper Conductor Diameter: Φ0.4~Φ0.8(mm) | |
Environment Characteristic | Storage Tempreture: 40 to 70°C |
Operating Temperature : 10 to 60°C | |
Relative Humidity: 95%, noncondition | |
Electrical Performance | Insulation resistance: 1000 Mohms minimum |
Contact resistance :7 mohms maximum | |
Dielectric intensity: AC 1000 Vrms 50Hz or 60Hz in 60s |
Cat.5e Performance Toolless Quick Connect Connection Module with Gel YH-2810B ,widely asked for replacement of 3M Quick connect module.There is single pair test probe YH-2827 for test.Highly price performance offered,with good quality.
We make sure that every product is 100% tested in the factory before packing.
Our products are popular with world's Telecom operator and users.Clients from America, South America, Europe,Asia and Africa and happy with our quality.We can offer OEM and ODM service according to customer's requirement as well. Better quality leads to more success ! One hundred successful orders lost in a complaint !
Order to be delivered goods within 7-10 days after we received your payment usually.For exact date,please check with our sales. Meanwhile,we could provide competitive shipping service for you, by sea, by air or by express. Appointed forwarder is also available as you prefer.
Contact US !
Contact Person: Miss. Xiang